fisher 3 wire diagram to two wires

fisher 3 wire diagram to two wires

2 min read 05-02-2025
fisher 3 wire diagram to two wires

Many industrial processes utilize Fisher valve positioners, known for their precision and reliability. While 3-wire systems offer versatility with separate power, signal, and feedback lines, migrating to a 2-wire system can simplify wiring, reduce costs, and improve overall system efficiency. This guide explains the process of converting a 3-wire Fisher valve positioner to a 2-wire configuration, emphasizing safety and practical considerations.

Understanding the Differences: 3-Wire vs. 2-Wire Systems

Before diving into the conversion, let's clarify the distinctions between these two systems:

3-Wire System: This traditional setup uses three wires:

  • Power: Supplies voltage to operate the positioner.
  • Signal: Carries the control signal from the controller to the positioner.
  • Feedback: Transmits the valve's actual position back to the controller.

2-Wire System: This more streamlined system uses only two wires:

  • Power & Signal: A single wire carries both power and the control signal.
  • Feedback: The feedback signal is transmitted over the second wire. This often employs techniques like current loops or other signal-encoding methods.

The key advantage of a 2-wire system is its simplified wiring, leading to reduced installation and maintenance costs. However, the conversion requires careful planning and potentially specialized components.

Steps for Converting a 3-Wire Fisher Valve Positioner to 2-Wire

The specific steps will depend on the exact Fisher positioner model and the chosen 2-wire communication protocol (e.g., 4-20mA current loop). Consult the positioner's documentation for detailed instructions and safety precautions. Always disconnect power before working on any electrical equipment.

1. Assess Compatibility: Not all Fisher valve positioners are compatible with a 2-wire conversion. Check the positioner's specifications and documentation to confirm its suitability for this modification. Some might require additional hardware or firmware updates.

2. Choose a Suitable 2-Wire Interface: You'll need an interface module or converter that can translate the 3-wire signals into a 2-wire protocol compatible with your control system. This might involve using a dedicated fieldbus module or other specialized hardware.

3. Wire the Positioner: This step is crucial and demands precision. Incorrect wiring can damage the positioner or the control system. Follow the wiring diagram provided with the 2-wire interface module carefully. This diagram will specify how to connect the power, signal, and feedback lines to the new interface. Double-check all connections before powering up.

4. Configure the Control System: The control system needs to be configured to work with the new 2-wire communication protocol. This might involve adjustments to the communication parameters, I/O settings, and scaling factors. Refer to your control system's manual for detailed configuration procedures.

5. Test and Commission: After completing the wiring and configuration, thoroughly test the system to ensure proper operation. Verify that the valve positioner responds correctly to control signals and that the feedback signal is accurately transmitted to the controller.

Safety Precautions and Considerations

  • Lockout/Tagout: Always follow proper lockout/tagout procedures before working on electrical equipment.
  • Grounding: Ensure proper grounding to prevent electrical shocks and damage.
  • Compatibility: Verify the compatibility of all components before proceeding.
  • Documentation: Keep detailed records of all modifications made to the system.
  • Professional Assistance: If you're not comfortable with electrical work or lack the necessary expertise, consult a qualified technician.

This guide provides a general overview of the conversion process. The specific procedures might differ based on the Fisher positioner model and the control system used. Always prioritize safety and refer to the official documentation for detailed instructions and safety precautions. Improper installation can lead to equipment damage, system malfunctions, and safety hazards.